• information
APPLICATION:
Prefabricated branch cables are mainly used in middle and high-rise buildings. They are suitable for the power distribution system of residential buildings, office buildings, commercial buildings, hotels, hospitals, shopping malls, factories, mines, tunnels, airports, bridges, cultural and sports venues and other projects. and they are suitable for fixed installation and laying outdoor and indoor, cable shaft and cable tray.
STANDARDS:
JB/T 10636, Q320481SS516, GB/T12706.1, IEC60502-1, IEC60228, IEC60332-1.
TYPE & CONSTRUCTION
FZ-YJV-0.6/1kV or FZ-Z*YJV-0.6/1kV:
Conductor: Stranded circular compacted copper, class 2 IEC60228
Insulation: Cross-linked Polyethylene(XLPE)
Outer sheath: Polyvinyl chloride(PVC), or flame retardant PVC

Type FZ-WDZYJY-0.6/1kV:
Conductor: Stranded circular compacted copper, class 2 IEC60228
Insulation: Cross-linked Polyethylene(XLPE)
Outer sheath: low smoke halogen free flame retardant polyolefin(LSZH)

FZ-Z*NYJV-0.6/1kV fire resistant cable:
Conductor: Stranded circular compacted copper, class 2 IEC60228
Insulation: Mica tape + extruded cross-linked Polyethylene(XLPE)
Outer sheath: Polyvinyl chloride(PVC), or flame retardant PVC

Type FZ-WDZ*NYJY-0.6/1kV fire resistant cable:
Conductor: Stranded circular compacted copper, class 2 IEC60228
Insulation: Mica tape + extruded cross-linked Polyethylene(XLPE)
Outer sheath: low smoke halogen free flame retardant polyolefin(LSZH)

NUMBER OF CORES & CONDCUCTOR SIZES
  • Single core:Copper 16mm2~1000mm2
  • Two-core:Copper 16mm2~500mm2
  • Three-core:Copper 16mm2~400mm2
  • Four-core:Copper 16mm2~300mm2
  • Five-core:Copper 16mm2~300mm2
CORE INDENTIFICATION
  • Single Core: yellow
  • Two-core: red, blue, or printing numbers 1,0
  • Three-core:yellow, green, red or printing numbers 1,2,3
  • Four-core: yellow, green, red, blue or printing numbers 1,2,3,0
  • Five-core: yellow, green, red, blue, yellow/green or printing numbers 1,2,3,4,0.
SHEATH COLOUR:
Black, or as per order.
MAIN TECHNICAL PARAMETER:
Voltage range: 0.6/1kV
Maximum continuous operating temperature: 90℃
Maximum short circuit temperature(maximum duration 5s): 250℃
Minimum environment temperature for installation: 0℃
Minimum bending radius of cable: 15×O.D.

OPTIONAL CHARACTERISTICS ON REQUEST:

Flame retardant: Acc. to IEC60332-3-24(ZC), IEC60332-3-23(ZB), IEC60332-3-22(ZA)
Fire resistant: Acc. to IEC60332-1 (Mica Tape is added between conductor and insulation)
Low smoke halogen free: IEC61034, IEC60754 (for LSZH sheathed cable)
Anti-termite/anti-rodent
Low temperature use
UV resistant
A new branch cable with Mineral filler flexible special fire proof cable (type FZ-BBTRZ and FZ-NG-A(BTLY) ) is available.

Feedback form contact with us