Prefabricated Branch Cable 0.6/1kV With Copper Conductor PVC Insulated
APPLICATION:
Prefabricated branch cables are mainly used in middle and high-rise buildings. They are suitable for the power distribution system of residential buildings, office buildings, commercial buildings, hotels, hospitals, shopping malls, factories, mines, tunnels, airports, bridges, cultural and sports venues and other projects. and they are suitable for fixed installation and laying outdoor and indoor, cable shaft and cable tray.
STANDARDS:
JB/T 10636, GB/T12706.1, IEC60502-1, IEC60228, IEC60332-1.
Prefabricated branch cables are mainly used in middle and high-rise buildings. They are suitable for the power distribution system of residential buildings, office buildings, commercial buildings, hotels, hospitals, shopping malls, factories, mines, tunnels, airports, bridges, cultural and sports venues and other projects. and they are suitable for fixed installation and laying outdoor and indoor, cable shaft and cable tray.
STANDARDS:
JB/T 10636, GB/T12706.1, IEC60502-1, IEC60228, IEC60332-1.
TYPE & CONSTRUCTION:
Type FZ-VV-0.6/1kV or FZ-Z*VV-0.6/1kV:
- Conductor: Stranded circular compacted copper, class 2 IEC60228
- Insulation: Polyvinyl chloride(PVC)
- Outer sheath: Polyvinyl chloride(PVC) or flame retardant PVC.
Type FZ-Z*NVV-0.6/1kV fire resistant cable:
- Conductor: Stranded circular compacted copper, class 2 IEC60228
- Insulation: Mica tape + extruded Polyvinyl chloride(PVC)
- Outer sheath: Polyvinyl chloride(PVC) or flame retardant PVC
NUMBER OF CORES & CONDCUCTOR SIZES:
- Single core:Copper 16mm2~1000mm2
- Two-core:Copper 16mm2~500mm2
- Three-core:Copper 16mm2~500mm2
- Four-core:Copper 16mm2~300mm2
- Five-core:Copper 16mm2~300mm2
CORE IDENTIFICATION:
- Single Core: yellow
- Two-core: red, blue, or printing numbers 1,0
- Three-core:yellow, green, red or printing numbers 1,2,3
- Four-core: yellow, green, red, blue or printing numbers 1,2,3,0
- Five-core: yellow, green, red, blue, yellow/green or printing numbers 1,2,3,4,0
SHEATH COLOR:
Black, or other color upon request.
Black, or other color upon request.
MAIN TECHNICAL PARAMETER:
Voltage: 0.6/1kV
Maximum continuous operating temperature: 70℃
Maximum short circuit temperature(maximum duration 5s): 160℃
Minimum environment temperature for installation: 0℃
Minimum bending radius of cable: 15×O.D.
OPTIONAL CHARACTERISTICS UPON REQUEST:
Flame retardant(*): Acc. to IEC60332-3-24(ZC), IEC60332-3-23(ZB), IEC60332-3-22(ZA)
Fire resistant: Acc. to IEC60331
Anti-termite/anti-rodent
Low temperature use
UV resistant