This rubber sheathed movable flexible cable is suitable for power connection of underground movable coal mining equipment.
STANDARDS:
MT 818.5.
MY-0.38/0.66kV:
Conductor: flexible tinned copper conductor (class 5)
Insulation: ethylene-propylene rubber (EPR)
Core arrangement: single core, or three power cores plus one earth core
Outer sheath: Chlorinated Polyethylene(CPE)
MYP-0.38/0.66kV and MYP-0.66/1.14kV:
Conductor: flexible tinned copper conductor (class 5)
Insulation: ethylene-propylene rubber (EPR)
Insulation screen: semi-conducting screen over power core insulation
Core arrangement: three power cores plus one earth core
Outer sheath: Chlorinated Polyethylene(CPE)
Number of cores |
Conductor CSA (mm2) |
Single Core |
4 ∽ 400 |
4-Core (3+1) |
4 ∽ 185 |
CORE IDENTIFICATION:
- Single core: white
- 4(3+1) core: red, white, blue, black
Black (0.38/0.66kV)
Yellow (0.66/1.44kV)
USAGE CHARACTERISTICS:
Rated voltage: 0.38/0.66kV, 0.66/1.14kV
Maximum continuous conductor operating temperature: 90℃
Maximum conductor short circuit temperature: 250℃ (maximum duration 5Sec.)
Minimum installation ambient temperature: 0℃
Minimum bending radius for installation: 6xO.D.
CERTIFICATION:
MA certification