Rated voltage: 0.6/1kV, 1.8/3kV
  • information
APPLICATION:
These cables are fixed installation explosion-proof/dangerous area and area exposed to MUD; conventional conditions for LV cable use.
STANDARD:
IEC 60092-350, IEC 60092-376, NEK 606
CONSTRUCTION:
1.Conductor: Tinned copper conductor
2.Insulation: XLPE or EPR
3.Inner sheath: LSHF XLPO
4.Armour: Tinned copper wire braid
5.Outer sheath: LSHF cross-linked polyolefin (mud-resisting type)
RANGE OF CABLE:

Number of Cores

Cross-sectional area of

1-Core

1.0mm2~300mm2

2-Core

1.0mm2~120mm2

3-Core

1.0mm2~185mm2

4-Core

1.0mm2~120mm2

5-Core

1.0mm2~50mm2

7~37-Core

1.0mm2~2.5mm2

CORE IDENTIFICATION:
Single core: Black
Two cores: Blue, Brown
Three cores: Brown, Black, Gray
Four cores: Blue, Brown, Black, Gray
Five cores: Blue, Brown, Black, Gray, Black
Above five cores: Black with numbers
SHEATH COLOR:
Black, or as per order.
USAGE CHARACTERISTICS:
  • Rated voltage:0.6/1kV, 1.8/3kV
  • Maximum continuous conductor temperature at normal operation:90℃
  • Maximum short-circuit temperature (5 s maximum duration):250℃
  • Minimum ambient temperature for installation: 0℃
  • Minimum bending radius of cable: 6D
CERTIFICATION:
CCS
Feedback form contact with us
Product Catalog